Self Limiting Heat Cable - Self Limiting Cable - ELTRACE

  • Increase font size
  • Default font size
  • Decrease font size
Refrigeration Industry

Self Limiting cable for cold-room doors ESR-R-30

E-mail Print PDF

SELF-REGULATING HEATING TAPE ESR-R-30Refrigeration cable

SELF-REGULATING HEATING TAPE

ESR-R-30


THE UNIVERSAL SOLUTION TO YOUR PROBLEMS OF PROTECTING COLD-ROOM DOORS FROM FREEZING UP
Technical features:

 

  • ESR-R-30:  plain version.

Maximum surface temperature:

  • Switched off:  80°C.
  • Switched on:  65°C.

Supply voltage:  230 V.

  • Power: 27 W/m at 0°C
  • Power: 52 W/m at -30°C.

References     ESR-R-30

  • Section    0.57 mm²
  • Dimensions     Ø 6mm
  • Maximum length    80 m
  • Protection(Circuit breaker curve C)  25 A

Read more...
 

Self Limiting Cable - Slidding door - ESR-R-40

E-mail Print PDF

Round Self regulating cableREFRIGERATION CABLE

Heating Tapes - ESR-R-40

Self Limiting Tapes 40w/m @ 0°C

THE UNIVERSAL SOLUTION FOR YOUR PROBLEMS OF PROTECTING COLD ROOM SLIDING DOORS FROM FREEZING UP

 

Technical features:

  • Maximum surface temperatur 55°C.
  • Supply voltage: 230 V. Power
  • 40 W/m @ 0°C.
  • 50 W/m @ –20°C.
  • Maximum length circuit: 125m
  • Weight: 41.5g/m
  • Conductor : Stranded nickelled copper 7 x 0.32mm
  • Diameter 1.43mm
  • Section 0.57mm²
  • Extrusion : semi conductive compound
  • Dimensions : 4.10mm x 4.40mm
  • Insulation White thermoplastic polymer
  • Radial thickness 0.85mm
  • Thickness 5.6mm +/- 0.4mm
  • Width 6.1mm +/- 0.4mm

Read more...